Isihlanzi se-Beckman Coulter Hematology Analyzers siyisisombululo se-enzymatic, -sokuhlanza esisebenzayo esiklanyelwe ukususa amadiphozithi amaprotheni, udoti wamaselula, namahlule e-fibrin emigwaqweni ewuketshezi ngesikhathi sokulungiswa okuzenzakalelayo okujwayelekile.
Iyini I-Hematology Analyzer Cleaner?
Isihlanzi se-hematology sohlaziyo yisihlanzi esisebenzayo se-alkaline esakhelwe ukuncibilikisa izinsalela zezinto eziphilayo, sinqande imvula yamaprotheni, nezikhala zokubala ezihlanzekile, amaseli agelezayo, nezinaliti zesampula ezibalini zamaseli ezizenzakalelayo.
Iqhaza Ekulungisweni Kwesihlaziyi
Ivimbela ukuvaleka kokuvula:Incibilikisa i-protein buildup ezungeze imbobo ukuze kugcinwe isilinganiso esizinzile se-impedance kagesi kanye nosayizi wamaseli.
Isusa ukuphazamiseka kwangemuva:Ixubha izingxenye zegazi eziyinsalela kanye nemfucumfucu evela kumaseli okugeleza ukuze kuncishiswe amaphutha esibalo sangemuva ekuqaliseni kwesampula okulandelayo.
Ivikela ama-fluidics angaphakathi:Yehlisa idiphozithi yekristalu kanye nokwakheka kwe-biofilm ngaphakathi kwamashubhu angaphakathi, ama-valve wokuncinza, namaphampu okulinganisa.
Uhlelo Lokuhlanza
Ukuhlanza i-probe:Ihlanza izinsalela zegazi kanye namaphrotheni ajiyile kusukela endaweni yangaphakathi nangaphandle yesampula ye-aspiration probe ngemva kwawo wonke umjikelezo wokuhlola.
Ukuhlanza i-Fluidics:Ihlanza amagumbi okubala, okugeza okuxutshwayo, imigudu yokulahlwa kwemfucuza, kanye namashubhu asebenza ngogesi ngesikhathi sezinqubo zokugungiswa okuzenzakalelayo.
Ukuhlanza isistimu:Incibilikisa i-organic build-up kanye nefilimu ye-fibrin phakathi nokuvalwa kwansuku zonke noma imijikelezo yokuhlanza ejulile yamasonto onke-.
Ukunakekelwa okujwayelekile:Igcina isisekelo somfutho we-hydraulic kanye nokungaguquguquki kwesivinini samanzi kuwo wonke amasekethe a-fluidic phakathi nezinqubo zokulungisa ezihleliwe.
Uchungechunge lwe-Analyzer oluhambisanayo
- 3-Ingxenye Automated Hematology Analyzers
- 5-Ingxenye Automated Hematology Analyzers
- Ukulungiselela Amaslayidi Okuzenzakalelayo kanye namamojula anemibala
Inqubo Yokuhlanza Nokusetshenziswa Okunconyiwe
Isondlo Sokuvalwa Kwansuku zonke:Qalisa ukuphela okuzenzakalelayo-komjikelezo{1}}wosuku lokuwashwa kokusetshenziswa kubonwa; isistimu idonsa ngokuzenzakalelayo umthamo omisiwe wokuhlanza ngenethiwekhi ye-fluidic.
Ukuhlanza Kwamasonto onke:Hlela umjikelezo ojulile wokugeza usebenzisa imenyu yokulungisa, ungenise isicoci egunjini lezinzwa ukuze sicwiliswe imizuzu eyi-10 kuya kweyi-15 ngaphambi kokulandelanisa okuzenzakalelayo kokuwasha.
Ukuvala{0}}okungahleliwe:Sebenzisa iphrothokholi ezinikele yokugezwa kwe-aperture noma i-probe wash uma izibalo zangemuva zidlula ukubekezelela okuyisisekelo okucacisiwe noma izexwayiso zengcindezi yesistimu zenzeka.
Imininingwane Yomkhiqizo
|
Ipharamitha Yezobuchwepheshe |
Ukucaciswa / Inani |
|
Isimo Somzimba |
Isixazululo esicacile, esinamanzi |
|
Umbala |
Ayinambala ukuya kokuphuzi ngokukhanyayo |
|
I-pH Inani (25 degree) |
9.5 – 11.5 |
|
I-Osmolality |
300 – 450 mOsm/kg |
|
Ukuminyana (20 degree) |
1.010 – 1.030 g/cm³ |
|
Izingxenye Ezisebenzayo |
Ama-enzyme e-proteolytic,-ama-ionic surfactants |
|
Ukubala kwezinhlayiya |
Izinhlayiya > 0.5 µm Ngaphansi noma kulingana nokubala okungu-100/mL |
|
Ukuhambisana Kwezinto ezibonakalayo |
Insimbi engagqwali, i-PTFE, ishubhu ye-silicone, ama-acrylic manifolds |
|
Ukuthobela Ukukhiqiza |
I-ISO 13485 ejwayelekile iqinisekisiwe |
Iphakheji kanye Nesitoreji
Izinketho zokupakisha:500 mL ibhodlela, 1 L ibhodlela, 2 L ibhodlela, 5 L isitsha.
Izinga Lokushisa Lesitoreji:Gcina ku-2℃kuya ku-35℃endaweni eyomile kude nelanga eliqondile.
Impilo Yeshelufu:Izinyanga ezingama-24 kusukela ngosuku lokukhiqiza ezitsheni ezivaliwe zangempela.
Vula-Ukuzinza Kwebhodlela:Izinsuku ezingama-60 lapho zigcinwe ngaphansi kwezimo zemvelo ezinconyiwe.
Ama-reagents ahlobene
I-Diluent ye-Hematology Analyzers:Isixazululo se-Isotonic sokumiswa kweseli, usayizi, nokulawula ukuzinza kwangemuva.
I-Lyse Reagent ye-Hematology Analyzers:I-reagent ye-Hemolyzing yokubhujiswa okusheshayo kwe-erythrocyte nokunqunywa kwe-hemoglobin.
Isixazululo se-Rinse sabahlaziyi be-Hematology:Isixazululo se-Hydraulic wash for intermediate circuit flushing phakathi kokugijima kwesampula.
Isicoci se-Enzymatic Esigxilisiwe:Ukucwilisa-ukwakheka kokucwilisa ukuze kususwe izithiyo ezinzima ezindleleni zama-hydraulic.
imibuzo ejwayelekile ukubuzwa
Q: Imuphi umsebenzi oyinhloko walesi sihlanzi kubahlaziyi be-hematology?
IMP: Isihlanzi sincibilikisa amadiphozithi amaprotheni eselula, sisula izindlela eziwuketshezi, sihlunga izinaliti zamasampula, futhi sinqande ukunqwabelana endaweni ephumela ngaphandle ukuze kugcinwe ukunemba kokulinganisa okuyisisekelo.
Q: Ingabe lesi sihlanzi sibangela ukugqwala kwamavalvu ensimbi yangaphakathi noma amashubhu?
A: Cha. Ukwakhiwa kusebenzisa ama-surfactants nama-ejenti agcina kumthamo ahambisana nezinto ezijwayelekile eziwuketshezi, okuhlanganisa i-silicone, i-PTFE, insimbi engagqwali, nama-acrylic manifolds.
Q: Lo mkhiqizo uqhathaniswa kanjani mayelana nokusebenza kwe-fluidic?
IMP: Lesi sihlanzi sifana namapharamitha adingekayo ngokomzimba namakhemikhali, okuhlanganisa i-pH, ukuminyana, i-osmolality, nomsebenzi we-proteolytic, oqinisekisa ukuziphatha kwe-hydraulic ngaphandle kokudinga ukulungiswa kwesisekelo.
Umbuzo: Kuyini ukuzinza kwebhodlela-okuvulekile kwesicoci?
A: Umkhiqizo uhlala uzinzile izinsuku ezingama-60 ngemuva kokuvulwa lapho ugcinwe ngokwezinga lokushisa elicacisiwe (2℃kuya ku-35 degree) futhi uvalwe lapho ungasetshenziswa.
Q: Ingabe lesi sihlanzi silungele izinqubo zokuvala shaqa ezizenzakalelayo zansuku zonke?
A: Yebo. Isihlanzi sihlanganisa ngokuqondile nokuvala shaqa okuzenzakalelayo, ukucwiliswa kwamaviki onke, kanye namaphrothokholi okugeza okuvula umnyango kulo lonke uchungechunge lwezinsimbi ezisekelwayo.
Amashadi ashisayo: isihlanzi se-beckman coulter hematology analyzers, i-China cleaner ye-beckman coulter hematology analyzers abakhiqizi, abahlinzeki