I-CBC Analyzer Calibrator inikeza amanani anembile, alandelekayo okulinganisa okulinganisa abahlaziyi be-hematology abazenzakalelayo, isungula ukunemba okuyisisekelo kwamapharamitha afaka i-WBC, i-RBC, i-HGB, i-MCV, ne-PLT.
Yiziphi Izilawuli / Izikali Ze-Hematology?
Izilawuli ze-hematology nezilinganisi ziyisipesheli, ireferensi-yebanga lezinto zebhayoloji eziklanyelwe ukugcina amazinga okulinganisa elabhorethri.
- Izikali ziqukethe ukugxila okwaziwayo kwezingxenye zeselula ezisetshenziselwa ukusetha nokulungisa isikali sokulinganisa esiyisisekelo sabahlaziyi be-hematology.
- Izilawuli zingamasampuli okuhlola azinzile asetshenziswa nsuku zonke noma ngokushintshwa-ngo-ngesisekelo sokushintsha ukuze kuqashwe ukunemba okuqhubekayo nokukhiqizwa kabusha kwesistimu ngemva kokusungulwa kokulinganisa.
Ngokungafani nama-reagents ajwayelekile asebenzayo enza ukucutshungulwa kweseli phakathi nemijikelezo evamile yokusebenza, izikali nezilawuli zisebenza njengamazinga ereferensi obuningi adingekayo ukuze kuqinisekiswe ukuhlaziya nokuthobela ikhwalithi.
Iqhaza Ekulawuleni Ikhwalithi Ye-Hematology
Ukugcina ukunemba kokuhlaziya ekuhloleni inani legazi eliphelele kudinga ukulungiswa kwereferensi okuhlelekile.
Ukulandela Ukulinganisa:Iqondanisa amashaneli e-optical ne-electrical impedance nezindlela zereferensi ezaziwayo emhlabeni jikelele.
Okuthunyelwe{{0}Ukulungiswa Kabusha Kokulungisa:Ibuyisela ukunemba kwesistimu ngemva kokulungiswa kokubona, ukushintshwa kwengxenye ye-fluidic, ukulinganiswa kabusha kwezinzwa, noma ukuseviswa kwezinsimbi ezinkulu.
Ukulungiswa kwe-Reagent Lot:Ilungisa ukushintshwa kokubona okuyisisekelo lapho ishintsha phakathi kokukhiqiza okuningi kwama-reagents asebenzayo.
Ukuthobela Umthetho:Ifeza izimfuneko zenqubo yokusebenza evamile ngaphansi kwezinhlaka zokugunyazwa zaselabhorethri.
Control Levels / Isicelo
Ukuze uthole izinqubo zokulawula ikhwalithi eziphelele ezilandela ukulinganisa, amasistimu okulawula i-hematology asebenza kuzo zonke izici ezintathu ezihlukene zomzimba:
Izinga eliphansi:Ihlola ukuzwela kwensimbi ngezibalo zamaseli eziphansi ngokungavamile. Ibalulekile ekuqinisekiseni imibundu yesinqumo somtholampilo se-anemia enzima, i-leukopenia, ne-thrombocytopenia.
Izinga Elijwayelekile:Iqinisekisa ukunemba kokulinganisa ngaphakathi kwamabanga ajwayelekile okuphila ukuze kuhlolwe isiguli okuvamile.
Izinga eliphezulu:Ihlola impendulo yomtshina wokuhlaziya ekugxilweni okuphezulu kwamaselula ngesikhathi se-leukocytosis, i-erythrocytosis, noma i-thrombocytosis.
Ukulawula ngokumelene ne-Calibrator
|
Ipharamitha Yezobuchwepheshe |
I-CBC Analyzer Calibrator |
I-Hematology Control (Ephansi / Evamile / Ephakeme) |
|
Umsebenzi Oyinhloko |
Ilungisa isisekelo sensimbi futhi isetha izici zokuphendula |
Iqinisekisa ukunemba kokulinganisa okuqhubekayo nokuzinza |
|
Ukusebenzisa Imvamisa |
I-Periodic (Ukufakwa, ukulungiswa, izinguquko ze-reagent lot) |
Nsuku zonke, shift{0}ngokusekelwe, noma ngenqwaba yokuhlola |
|
Amanani Okuhlosiwe |
Inani lesabelo esingaguquki esisodwa ipharamitha ngayinye enemikhawulo ewumngcingo |
Inani elichaziwe lihluka phakathi kokugxilisa okuphansi, okujwayelekile, nokuphezulu |
|
Iqhaza Lezibalo |
Ishintsha ukuthambeka kokulinganisa nokunqamula kumemori yohlelo |
Amaphoyinti edatha ye-Plot kumashadi e-Levey-Jennings ukuze kutholwe ukukhukhuleka |
|
I-Metrology Standard |
Izinga eliyisisekelo noma lesibili lezinto eziyisethenjwa |
Izinto zokuqapha ikhwalithi yesibili |
I-Hematology Analyzers Ehambisanayo
Yakhelwe ngezingxenye zebhayoloji ezizinzile ukuze ifane nezici zesampula yegazi lonke, isekela ukuhlanganiswa kuzo zonke izinkundla zamathuluzi ahlukahlukene:
3-Izingxenye Ezihlukile Zesistimu:I-impedance{0}izinto zokubala ezisekelwe ku-Impedans ezidinga ukulinganisa kwe-WBC, RBC, HGB, HCT, MCV, MCH, MCHC, ne-PLT.
5-Izingxenye Ezihlukile Zesistimu:I-multi-i-angle laser scatter, i-flow cytometry, nezinkundla zokungcolisa amakhemikhali ezidinga ukulinganiswa okuhlukile kuzo zonke{1}}izibalo zabantu.
Amanani Abelwe / Amapharamitha
Inkatho ngayinye iqinisekiswa ngokuqhathaniswa nezindlela eziyisethenjwa futhi inikezwa-ishidi Levelu Lokuhlola Elikhethekile eliqukethe amanani okuqondiwe nobubanzi obamukelekayo:
|
Ipharamitha |
Isifinyezo |
Ibanga Lethagethi Elijwayelekile |
Iyunithi eyabelwe |
|
Amangqamuzana Amhlophe Egazi |
WBC |
6.5 - 8.5 |
x10^9/L |
|
Amangqamuzana Egazi Abomvu |
I-RBC |
4.00 - 5.00 |
x10^12/L |
|
IHemoglobin |
I-HGB |
120 - 150 |
g/L |
|
Ivolumu ye-Corpuscular okusho |
I-MCV |
80.0 - 95.0 |
fL |
|
Ama-Platelets |
I-PLT |
180 - 280 |
x10^9/L |
Imininingwane Yomkhiqizo
|
Ukucaciswa kwento |
Imininingwane |
|
Igama Lomkhiqizo |
I-CBC Analyzer Calibrator |
|
Ukwakhiwa |
Ukumiswa kwamaselula okuzinzile endaweni yokulondoloza |
|
Isimo Somzimba |
Ukumiswa koketshezi |
|
Amapharamitha Abelwe |
I-WBC, RBC, HGB, MCV, PLT, HCT |
|
Gcwalisa Ivolumu |
2.0 mL / 3.0 mL ibhodlela ngalinye |
|
Ukulandeleka |
Kubhekiselwe kumazinga ereferensi yamazwe ngamazwe |
|
Isitifiketi Sokukhiqiza |
ISO 13485 |
|
Izinketho zokupakisha |
-amakhithi e-vial amaningi anamashidi{1}akhethekile okuhlola ibhakhodi |
Isitoreji Nokuqina
Ukulawula izinga lokushisa kulondoloza ubuqotho be-membrane yeseli nokuzinza kwepharamitha kuyo yonke impilo yomkhiqizo:
Ithempelesha Yesitoreji Engavuliwe:2 kuya ku-8 degrees Celsius. Ungaqandi.
Impilo Yeshelufu Engavuliwe:Izinsuku ezingama-60 ukusuka osukwini lokukhiqiza lapho zigcinwe ku-2 kuya ku-8 degrees Celsius.
Vula-I-Vial Stability:Izinsuku eziyi-7 lapho igcinwe ivalwe ngokuqinile ku-2 kuya ku-8 degrees Celsius ngokushesha ngemva kokuthatha amasampula.
Ukuvikelwa Kokushisa:Ithunyelwa ngezinga lokushisa{0}}amaphakheji agqunyiwe agqunyiwe ukuze kuvikelwe ukuqina kokushisa ngesikhathi sokuthutha.
Ukuqinisekisa ikhwalithi
Amaphrothokholi okukhiqiza agcina inkatho-yo{1}}ukuvumelana okuningi nokuqinisekiswa kokulinganisa:
Ukuqinisekiswa kwe-Metrological:Yonke ingxenye yokulinganisa inikezwa amanani kusetshenziswa amathuluzi ayireferensi aqinisekiswe ngokumelene namazinga omhlaba.
Ukuhlolwa kwe-Homogeneity:Ukusampula kwe-vial okungahleliwe kuyo yonke imijikelezo yokukhiqiza kuqinisekisa ukufana{0}}kwe-lot (I-Coefficient of Variation<= 1.0%).
Ukuqapha Ukuzinza:Isikhathi sangempela-nokuhlolwa kokuqina okusheshisiwe kwenziwa kuyo yonke inqwaba yokukhiqiza.
Amadokhumenti Okulawula:Isitifiketi Sokuhlaziya Nedatha Yezokuphepha sinikezwe ngendawo ngayinye yokulethwa.
FAQ
Q: I-analyzer kufanele ilinganiswe kangaki kusetshenziswa isilinganisi?
IMP: Ukulinganisa kabusha kuyadingeka ekufakweni kokuqala kwethuluzi, kulandela ukunakekelwa okujwayelekile kokuvimbela, ngemva kokulungiswa okukhulu, lapho imiphumela yokulawula ikhwalithi yansuku zonke ibonisa ukuchema okungaguquki, noma lapho ushintshela endaweni entsha ye-reagent ngokuya ngezivumelwano zaselabhorethri.
Q: Uyini umehluko phakathi-nokuqina kwe-vial evulekile nempilo yeshelufu engavuliwe?
IMP: Impilo yeshelufu engavuliwe isho isikhathi lapho i-calibrator igcina amanani abekiwe lapho egcinwe evaliwe ku-2 kuya ku-8 degrees Celsius. Ukuzinza-kwevial kubonisa inani lezinsuku lapho umkhiqizo uhlala unembile ngemva kokuvulwa, inqobo nje uma uphathwa ngaphansi kwezimo ezihlanzekile futhi ubuyiselwa ku-2 kuya ku-8 degrees Celsius ngokushesha ngemva kokusetshenziswa.
Umbuzo: Ingabe izilawuli ze-hematology zingasetshenziswa esikhundleni se-calibrator?
A: Cha. Ilawula ukunemba kwesistimu kubo bonke ububanzi bezinombolo, kuyilapho izikali zinikeza amanani anembile ayizethenjwa asetshenziswa isofthiwe yokuhlaziya ukulungisa amajika empendulo yezibalo kanye nezici zokulinganisa eziyisisekelo.
Q: Kufanele ilungiswe kanjani i-calibrator ngaphambi kokuthatha isampula?
A: Khipha ibhodlela ekugcinweni kwe-2 kuya ku-8 degrees Celsius futhi uyivumele ukuthi ilingane nezinga lokushisa elilingana negumbi (ama-degrees Celsius ayi-15 kuye kwangama-30) imizuzu eyi-15. Hlanganisa kahle ngokushintshashintsha okumnene, okuphelele ngaphambi kokwethula isampula kuphenyo lwesampula. Gwema ukuzamazama ukuze uvimbele ukuphazamiseka kweseli noma amabhamuza omoya.
Q: Amazinga okushisa agcinwa kanjani ngesikhathi sokuthunyelwa kwamanye amazwe?
I: Ama-oda apakishwe emaphaketheni ashisayo ngezinga lokushisa-izinto ezivikelayo kanye namaphekhi abandayo adizayinelwe ukugcina u-2 kuya ku-8 degrees Celsius phakathi nokuhamba emoyeni.
Amashadi ashisayo: i-cbc analyzer calibrator, China cbc analyzer calibrator abakhiqizi, abahlinzeki