I-HGB Lyse Reagent ye-HORIBA ABX Hematology Analyzers iyisixazululo samakhemikhali se-cyanmethemoglobin-esenzelwa ukulinganisa kokugxilisa kwe-hemoglobin nokubala okuhlukile kwamaseli amhlophe egazi. Ukwakheka kwephula ulwelwesi lwe-erythrocyte, kuguqule i-hemoglobin ekhululiwe ibe inkimbinkimbi ye-chromophore enenani eliphakeme lokumuncwa okukhanyayo ku-540 nm, futhi igcine imigqa ecacile ye-fluidic ngesikhathi sokufunda okuzenzakalelayo kokubona.

Isingeniso Somkhiqizo

I-HGB Lyse Reagent ye-HORIBA ABX Hematology Analyzers iyisixazululo samakhemikhali se-cyanmethemoglobin-esenzelwa ukulinganisa kokugxilisa kwe-hemoglobin nokubala okuhlukile kwamaseli amhlophe egazi. Ukwakheka kwephula ulwelwesi lwe-erythrocyte, kuguqule i-hemoglobin ekhululiwe ibe inkimbinkimbi ye-chromophore enenani eliphakeme lokumuncwa okukhanyayo ku-540 nm, futhi igcine imigqa ecacile ye-fluidic ngesikhathi sokufunda okuzenzakalelayo kokubona.

 

Iyini i-Hematology Analyzer Lyse Reagent?

 

I-hematology analyzer lyse reagent iyisixazululo samakhemikhali esikhethekile esinama-surfactants asebenzayo aphula ngokukhetha ulwelwesi lwamaselula kumasampula egazi. Ngesikhathi sokunqunywa kwe-hemoglobin, i-lysing agent ibhubhisa amangqamuzana egazi abomvu ukuze ikhulule ulwelwesi-i-hemoglobin eboshiwe, iyiguqule ibe inkimbinkimbi ekhanyayo-emunca ukuhlola ukuminyana kwe-optical density kumaza amaza e-spectrophotometric athile.

 

Isicelo ku-Hematology Analysis

 

Ukulinganisa Ukugxila KweHemoglobin
Ihambisa amaseli abomvu egazi ukuze ikhulule i-hemoglobin ye-intracellular futhi iyiguqule ibe inkimbinkimbi ye-chromophore ezinzile yokufunda nge-spectrophotometric ku-540 nm.
Umehluko weLeukocyte nokubala
Inciphisa ngokukhethekile i-cytoplasm yamangqamuzana egazi amhlophe kuyilapho ilondoloza izakhiwo zenuzi ukuze inike amandla-ivolumu esekelwe kusayizi eziteshini zokulinganisa i-impedance.
I-Optical Flow Cell Maintenance
Incibilikisa imfucumfucu yamaseli ayinsalela, ivimbele ukunqwabelana kwamaprotheni kanye nemvula ye-lipid ngaphakathi kwama-optical cuvettes phakathi nemigijimo yokuhlaziya eqhubekayo.

 

Uchungechunge lwe-Analyzer oluhambisanayo

 

I-ABX Micros Series

I-Micros 60, iMicros ES 60

Uchungechunge lwe-ABX Pentra

I-Pentra 60, i-Pentra 60 C+, i-Pentra 80, i-Pentra XL 80

Uchungechunge lwe-ABX Yumizen

Yumizen H500, Yumizen H550

 

Imininingwane Yomkhiqizo

 

Ipharamitha Yezobuchwepheshe

Ukucaciswa / Izinga elilinganiselwe

Ifomu Lomzimba

Uketshezi oluhlanzekile, olungenambala,{0}}olungenazinhlayiyana

I-pH Inani (25 degree)

7.00 – 7.40

I-Osmolality

300 – 340 mOsm/kg

I-Absorance Blank (540 nm)

Ngaphansi noma kulingana no-0.005 AU

Okuqukethwe kwe-Cyanide

0.00% (I-Cyanide{1}Ukwakhiwa Kwamahhala)

Particulate Background (>2 µm)

Ngaphansi noma kulingana nokubala okungu-5/mL

I-Correlation Coefficient (R)

Kukhulu noma kulingana no-0.99 (Ngokuqhathaniswa ne-reagent yasekuqaleni yomkhiqizi)

Qoqa-ukuze-Ukwehluka kweqoqo

< 1.5% CV

Impilo Yeshelufu Engavuliwe

Izinyanga ezingama-24 (Igcinwe ku-2℃- 35 degree)

Vula-I-Vial Stability

Izinsuku ezingama-60 (Ezingeni lokushisa elilawulwayo legumbi)

 

Izici Eziyinhloko

 

I-Cyanide-Ukwakhiwa Kwekhemikhali Kwamahhala
Ikhiqiza udoti{0}okungenabo ubuthi obuwuketshezi, iqeda izidingo ezikhethekile zokungalungi kwemfucuza eyingozi ukuze ilahlwe emtholampilo.

0.1 µm Ukuhlunga okuningi-Isiteji
Icutshungulwe ngezihlungi eziphelele ze-membrane ezingu-0.1 µm, igcina ibala lezinhlayiyana ezingemuva ngaphansi kwezibalo ezingu-5/mL ukuze kuvikelwe ama-micro-ama-fluidic apertures.

Ukulawulwa kwengemuva le-Optical Baseline
Ibamba i-reagent absorbance engenalutho ku-0.005 AU noma ngaphansi ukuze kuqinisekiswe ukusabela kokumunca okuqondile kuwo wonke amabanga abanzi okulinganisa i-hemoglobin.

I-Electrolyte & Conductivity Alignment
Ifanisa amandla ajwayelekile e-ayonic e-fluidic ukuze kugcinwe izinga lokugeleza kwesampula ezinzile ngaphandle kokulinganisa kabusha izici zokutholwa kwesistimu.

Okungahlangani-ku-Corrosive Surfactant Blend
Yakhelwe ngaphandle kwezinyibilikisi ze-organic ezinolaka ukuze kuvinjelwe ukuqhekeka kwendawo noma ukufiphala kumaseli e-acrylic optical flow kanye neshubhu ekhanyayo.

 

Iphakheji Nesitoreji

L high-amabhodlela e-polyethylene (HDPE) aphezulu kanye neziqukathi ezingu-5 L HDPE.
Ibanga Lokushisa Lesitoreji:2 kuya ku-35℃(36 degrees F kuya ku-95 degrees F).
I-Thermal Shipping Protection:Iziqukathi zigcwele ama-thermal linings afakwe ngaphakathi ukuze kuvikelwe ukuqina komkhiqizo ngokumelene nokwehluka kwezinga lokushisa elizungezile ngesikhathi sokuthutha olwandle nomoya.
Ukuvala Ubuqotho:Ifaka-ama-cap liner e-aluminium foil evaliwe ukuze kunqandwe ukuhwamuka koketshezi, i-ambient oxidation, nokuvuza ngesikhathi sokuthutha amazwe ngamazwe.

 

Ukukhiqiza Nokunikezela

 

ISO Class 7 Cleanroom Production

Kwakhiwe, kwahlungwa, futhi kwafakwa amabhodlela ngaphakathi kwamagumbi okuhlanza e-ISO Class 7 azenzakalelayo ukuze kunqandwe ukungcoliswa kwezinhlayiya kanye nama-microbial.

High-Izinga Lamanzi Ahlanzekile

Isebenzisa ama-ultra-amanzi ahlanzekile enziwe nge-deionized anokumelana okudlula u-18.2 MΩ·cm njengesisekelo se-solvent eyinhloko.

Kuvaliwe-I-Loop Processing Telemetry

Isebenzisa imikhumbi yokuxuba evalekile efakwe i-pH engaphakathi komugqa, i-conductivity, ne-viscosity telemetry ukuze iphoqelele inqwaba-kuya{1}}ukuvumelana kwenqwaba.

I-Lot Release Test Protocols

Yonke indawo yokukhiqiza ihlolwa nge-spectrophotometric, ukubalwa kwezinhlayiyana zangemuva, nokuhlolwa kokucindezeleka okushisayo ngaphambi kokukhishwa KweSitifiketi Sokuhlaziya.

 

Ama-reagents e-Hematology ahlobene

 

I-Hematology Diluent Solution

Isixazululo se-isotonic electrolyte esisetshenziselwa ukuhlanjululwa kwesampula yegazi lokuqala, ukuqiniswa kwevolumu yeseli, kanye nokuguquguquka komugqa we-fluid.

Isixazululo se-Enzymatic Cleaner

Isixazululo sokuhlanza i-proteolytic esakhelwe ukuncibilikisa amadiphozithi egazi amaprotheni asuka kubhavu wokuvula kanye nemigqa yemfucuza.

Isixazululo Sokuhlanza Isistimu

Uketshezi lokuwasha olususelwe ku-surfactant{0}okusetshenziselwe ukugeza okuzenzakalelayo kwendlela ewuketshezi phakathi kwemijikelezo yokucubungula isampula.

 

FAQ

 

Q: Ingabe le reagent ye-lyse idinga ukulungiswa kabusha kwesistimu uma ifakwa?

A: Amapharamitha womzimba wesistimu, ingcindezi ye-osmotic, namaphrofayela okumunca akhiwa ukuze afane nokucaciswa kwangempela. Ukulawulwa kwekhwalithi okujwayelekile kuyanconywa lapho ushintsha ama-reagent amaningi ngaphandle kokulungisa izilungiselelo zokuzuza kwesistimu.

Umbuzo: Ingabe i-cyanide-ukwakheka kwamahhala kufinyelela kanjani ukunemba kwesikali se-photometric?

A: I-surfactant iguqula i-hemoglobin ekhululiwe iyenze imidazole ezinzile-inhlanganisela ye-hemoglobin ekhiqiza i-spectrum yokumuncwa ku-540 nm efana nezindlela zomdabu ze-cyanmethemoglobin.

Q: Yiziphi izinyathelo zokupakisha zezokuthutha ezivikela ukuthunyelwa{0}}emizileni yezokuthutha enezinga lokushisa eliphezulu?

A: Ukwakhiwa kwamakhemikhali kuhlala kuzinzile phakathi kwe-2℃kanye ne-35 degree. Ukuthunyelwa kwamanye amazwe kusebenzisa omalayini beziqukathi ezishisayo-nezimbobo ezivaliwe ze-HDPE ukuze kuncishiswe ukwenyuka kwezinga lokushisa.

Q: Yiziphi izilawuli zobuchwepheshe ezivimbela amashubhu e-fluid kanye nokuvaleka kokuvula?

A: Ukuhlunga-okuningi kwesiteji ngo-0.1 µm wezihlungi eziphelele kususa ama-micro-ama-particle, kugcina isibalo sezinhlayiya zangemuva zibe noma ngaphansi kokuthi 5 count/mL.

Q: Imaphi amadokhumenti okuthobela ikhwalithi afakiwe ekuthunyelweni ngakunye?

A: Yonke impahla ethunyelwayo ihlanganisa-Isitifiketi Esiqondile Sokuhlaziya (CoA), Ishidi Ledatha Yokuphepha Okubalulekile (MSDS), Ishidi Ledatha Yobuchwepheshe (TDS), kanye nemibhalo yokuthobela ikhwalithi yokuphathwa kwekhwalithi ye-ISO.