I-Lyse Reagent Ye-Mindray 3-Ingxenye Yokuhlaziya I-Hematology

I-Lyse Reagent Ye-Mindray 3-Ingxenye Yokuhlaziya I-Hematology

I-Lyse Reagent ye-Mindray 3-Part Hematology Analyzers ihlunga ngokushesha amangqamuzana egazi abomvu futhi ilungise amangqamuzana amhlophe egazi ukuze athole umehluko onembile wezingxenye ezi-3 ze-leukocyte kanye nokunqunywa kwe-hemoglobin. Yakhelwe njenge-reagent eshintshayo eqondile, ihlanganisa ngaphandle komthungo emigqeni ye-fluidic ngaphandle kokulungiswa kabusha noma ukulungiswa kwehadiwe.

Isingeniso Somkhiqizo

I-Lyse Reagent ye-Mindray 3-Part Hematology Analyzers ihlunga ngokushesha amangqamuzana egazi abomvu futhi ilungise amangqamuzana amhlophe egazi ukuze athole umehluko onembile wezingxenye ezi-3 ze-leukocyte kanye nokunqunywa kwe-hemoglobin. Yakhelwe njenge-reagent eshintshayo eqondile, ihlanganisa ngaphandle komthungo emigqeni ye-fluidic ngaphandle kokulungiswa kabusha noma ukulungiswa kwehadiwe.

 

Iyini i-Hematology Analyzer Lyse Reagent?

 

I-Hematology analyzer lyse reagent iyisixazululo samakhemikhali esikhethekile esiklanyelwe ukudiliza ulwelwesi lwamaseli erythrocyte kuyilapho lulondoloza amaleukocyte esimweni esizinzile. Lokhu kubhujiswa kwamaseli okukhethekile kuvumela ukukala okunembile kokubona noma kukagesi kokugxiliswa kwe-hemoglobin futhi kuvumela ukuhlukaniswa kwamaseli amhlophe egazi abe ama-lymphocyte, ama-monocyte, nama-granulocyte.

 

Isicelo ku-Hematology Analysis

 

Ukubala Komehluko Wamangqamuzana Egazi Elimhlophe
Ngokukhetha incipha i-cytoplasm futhi ilondoloze i-nuclei yamangqamuzana amhlophe egazi, okuvumela ukuhlukana okucacile kube abantu abathathu abahlukene ngesikhathi sokulinganisa i-impedance.

Ukunqunywa Kwe-Hemoglobin Concentration
I-Lys amangqamuzana egazi abomvu ukuze akhulule i-hemoglobin eboshiwe, enze inkimbinkimbi ye-chromophore ezinzile yokufunda i-photometer absorbance ku-525 kuya ku-540 nm.

Ukulawula Ukubala Kwangemuva
Igcina isibalo esiphansi sokushaya kwesisekelo esiphansi ngaphakathi kweseli lokugeleza, ivimbela ukuphazamiseka kwesignali phakathi-nokuhlaziywa kwesifanekiso sevolumu encane.

 

Uchungechunge lwe-Analyzer oluhambisanayo

 

3-Ingxenye Automated Hematology Series
Idizayinelwe izinkundla ezijwayelekile{1}}ezihlukene eziyingxenye engu-3 ezisebenzisa i-dual-chamber impedance kanye namashaneli e-photometric.
I-Integrated Fluidic Connector Interfaces
Ifakwe umbala{{0}amakhodi avaliwe{1}}ama-loop caps namajoyinti e-probe afana nemigqa ye-fluidic inlet evamile.
Ukuqashelwa kwe-Reagent ezenzakalelayo
Isekela amasistimu wokulandela amanzi ajwayelekile ukuze kuqashwe inzuzo ye-reagent.

 

Imininingwane Yomkhiqizo

 

Ipharamitha Yezobuchwepheshe

Ukucaciswa / Inani

Isithenjwa Esijwayelekile

Ukubukeka Ngomzimba

Uketshezi oluhlanzekile, olungenambala,{0}}olungenazinhlayiyana

Ukuhlola Okubonakalayo

Inani le-pH

7.20 - 7.60 at 25 degree

Imitha ye-pH

I-Conductivity

15.0 – 20.0 mS/cm

I-conductometer

Ukubala kwangemuva kwe-WBC

Ngaphansi kuka-0.2 × 10⁹ / L

Ukuhlola Okuyisisekelo

Ukubala kwangemuva kwe-HGB

Ngaphansi noma kulingana no-1.0 g/L

Ukuhlola Okuyisisekelo

I-WBC Precision (CV)

Ngaphansi noma kulingana no-2.5%

Ukugijima Kwesampula Lomtholampilo

I-HGB Precision (CV)

Ngaphansi noma kulingana no-1.5%

Ukugijima Kwesampula Lomtholampilo

Uhlobo Lokwakha

I-Cyanide-Imahhala

Ukuhlaziywa Kwamakhemikhali

I-Shelf Life

Izinyanga ezingama-24 (Azivuliwe)

Ukuhlola Okusheshisiwe

Vula-I-Vial Stability

Izinsuku ezingama-60 (Kulawulwa ku-15-30 degree)

Ukuhlolwa-Kwesikhathi Sangempela

 

Izici Eziyinhloko

 

I-Cyanide-Ukwakhiwa Kwamahhala
Iqeda izingozi zamakhemikhali anobuthi, yenza lula ukwelashwa kwemfucuza yaselebhu futhi ihlangabezane nezindinganiso zamazwe ngamazwe zokulahla imvelo.

I-Erythrocyte Lysis esheshayo
Iqeda ukubhujiswa kwamangqamuzana egazi abomvu ngemizuzwana, ishiye imfucumfucu engaba yiziro ukuze ivimbele ukuvaleka kwendawo.

I-WBC Shrinkage enembile
Igcina ukuqina kolwelwesi lwe-leukocyte okuqondile ukuze kuqinisekiswe ukwehlukana kwabantu okubukhali kuma-histogram okusabalalisa amaseli.

Ukuphazamiseka Okuphansi kwe-Optical
Ikhiqiza amaphrofayili okumunca ukukhanya okuzinzile ukuze kutholakale inani elithembekile le-hemoglobin kuwo wonke amabanga aphelele alayini.

Okuningi-ku-Ukuvumelana Kwenqwaba
Kwenziwe ngaphansi kokulawulwa kwenqwaba okuzenzakalelayo ukuze kukhawulelwe phakathi{0}}nokwehluka kwepharamitha ye-lot ngaphakathi kwemikhawulo eqinile.

 

Iphakheji Nesitoreji

 

Inketho yokupakisha

Okubalulekile Kwesitsha

Izinga Lokushisa Lesitoreji

Isimo Sokuthumela

500 ml Ibhodlela

-I-Polyethylene Eminingi Ephezulu

I-2℃- 35℃(Ungaqandi)

I-ambient (Vikela ekushiseni)

1 L Ibhodlela

-I-Polyethylene Eminingi Ephezulu

I-2℃- 35℃(Ungaqandi)

I-ambient (Vikela ekushiseni)

5 L iCubitainer

I-Multi-Layer Flexible Box

I-2℃- 35℃(Ungaqandi)

I-ambient (Vikela ekushiseni)

 

Ukukhiqiza Nokunikezela

 

Imigqa Yokukhiqiza Ezenzakalelayo
Kwakhiwe kusetshenziswa amasistimu okulungisa uketshezi oluvaliwe kanye nokuhlunga okungu-0.1 μm okuncane-.

Cleanroom Packaging
Ifakwe emabhodleleni ezindaweni ezihlanzekile ze-Class 100,000 ukuze kuqinisekiswe ukukhululeka ekungcoleni kwamagciwane kanye nezinhlayiya eziphuma emoyeni.

Ukuqinisekiswa Kwekhwalithi
Yonke ingxenye yokukhiqiza iyaqinisekiswa kubahlaziyi abaqondiwe ngokumelene nezinto zokulawula izithenjwa ngaphambi kokukhishwa.

Global Custom Packaging Solutions
Inikeza amasayizi angokwezifiso evolumu, amalebula ayimfihlo, nokuthunyelwa kwenqwaba koketshezi okuklanyelwe abahlinzeki bezinto ezisizayo zezokwelapha.

 

Ama-reagents e-Hematology ahlobene

 

I-Diluent Yezihlaziyi Ze-Hematology Eziyingxenye Ezi-3
Isixazululo se-Isotonic sokuhlanjululwa kwesampula yegazi, ukulondolozwa kwevolumu yeseli, nokuhlanzwa komugqa we-fluid.

Isicoci se-Probe / Isicoci se-Enzymatic
Isixazululo esigxilisiwe sokusula sokususa ama-protein deposits kumasampula okuhlola kanye namagumbi okuxutshwa.

I-Maintenance Cleanser
-Indawo esebenza kanzima yokuwasha edizayinelwe ukuphela{{1}ko{2}}kosuku lokuguquguquka okumanzi kanye nokuvula imbobo.

 

imibuzo ejwayelekile ukubuzwa

 

Q: Ingabe lesi siphehli se-lyse singasetshenziswa ngokuqondile ngaphandle kokulungiswa kabusha kwensimbi?

A: Yebo. Amandla e-ionic, ukugxila kwe-surfactant, namaphrofayili okumunca ahambisana nokucaciswa kokuhlaziya okujwayelekile, okuvumela ukushintshwa okuqondile ngaphandle kokulungisa amapharamitha wokulinganisa.

Umbuzo: Ingabe lesi siphehli se-lyse sine-cyanide?

I: Cha. Ukwakheka kusebenzisa i-cyanide{1}}i-surfactant complex yamahhala ukuze kukale i-hemoglobin ngokuphepha kuyilapho kunciphisa izidingo zokulahlwa kwemfucuza yaselabhorethri eyingozi.

Q: Kwenzekani uma i-lyse reagent iba yiqhwa ngesikhathi sokuthutha?

A: Ukubanda kungabangela ukuhlukaniswa kwesigaba sama-reagents asebenzayo. Uma siqandisiwe, letha isiqukathi ekamelweni lokushisa (amadigri angu-15–30) bese ujikisa ngobumnene ukuze wenze i-homogenize ngokuphelele ngaphambi kokuhlolwa kwesisekelo.

Q: Lesi sikhungo siwuvimbela kanjani umsindo wangemuva nokuvaleka kwendawo?

A: Ukuhlunga okuphindwe kabili-isiteji esingu-0.1 μm kususa-ama-micron particulate, kuyilapho ukuxazululeka kolwelwesi lwe-stromal okuphelele kuqeda ukunqwabelana kwemfucumfucu yamaseli ngaphakathi{3}}kwezikhala ezincane.

Q: Yiziphi izinketho zokupakisha ezitholakalayo zama-oda amaningi?

A: Ukupakishwa okujwayelekile kufaka phakathi u-500 mL, 1 L, no-5 L ukucupha. Umumo wesiqukathi owenziwe ngokwezifiso, amalebula ayimfihlo, nokuthunyelwa kwenqwaba yemigqomo kungahlelwa ngokusekelwe ezidingweni zokuthenga.

Amashadi ashisayo: I-lyse reagent ye-mindray ezingxenyeni ezi-3 ze-hematology analyzer, i-China lyse reagent ye-mindray izingxenye ezi-3 ze-hematology analyzer abakhiqizi, abahlinzeki

Thumela ukuPhenya

whatsapp

Ifoni

Imeyili

Inquiry

isikhwama